Industrial Fire Pump Room
Industrial Fire Pump Room

Industrial Fire Pump Room

MOQ : 1 Unit

Industrial Fire Pump Room Specification

  • Flow Rate
  • 100 - 800 m3/h
  • Max Suction
  • 8 meters
  • Inlet/Outlet
  • DN100 / DN150 / DN200 (as per requirement)
  • Mounting Type
  • Base Plate Mounted
  • Theory
  • Centrifugal Fire Pump
  • Head Size
  • 30 - 150 meters
  • Frequency
  • 50 Hz / 60 Hz
  • Control System
  • Automatic / Manual Control Panel
  • Fuel Tank Capacity
  • 200 - 500 liters (diesel engine type)
  • Noise Level
  • <85 dB(A)
  • Caliber
  • 100mm - 200mm
  • Discharge Pressure
  • 2 - 16 Bar
  • Working Temperature
  • -10C to 80C
  • Features
  • Corrosion resistant, High efficiency, Easy maintenance
  • Speed
  • 1450 RPM / 2900 RPM
  • Voltage
  • 380V / 415V / 440V
  • Material
  • Cast Iron / Stainless Steel
  • Structure
  • Horizontal Split Case
  • Power
  • 15 kW - 110 kW
  • Standard
  • NFPA 20 / IS 15301 / UL Listed
  • Fuel Type
  • Electric / Diesel
  • Pressure
  • Up to 16 Bar
  • Usage
  • Industrial Fire Protection
  • Application
  • Fire Hydrant, Sprinkler, Deluge & Monitor Systems
  • Suction Type
  • Single Stage
  • Seals Type
  • Mechanical Seal
  • Priming
  • Self-priming / Manual priming
  • Pump Type
  • Main Fire Pump / Jockey Pump / Standby Pump
  • Capacity
  • Up to 800 m3/h
  • Fire Alarm Interface
  • Provision for BMS/Fire Panel integration
  • Coupling Type
  • Flexible coupling with guard
  • Enclosure
  • Weatherproof canopy available
  • Installation
  • Indoor/Outdoor fire pump room setup possible
  • Number of Pumps in Room
  • Typically 2 or 3 (Main + Standby + Jockey)
  • Test Line Outlet
  • Included
  • Certificates
  • Test Certificate, Factory Acceptance Report
  • Prime Mover
  • Electric motor or diesel engine
  • Cooling System
  • Closed loop water cooled or air cooled (diesel engine)
  • Base Frame Material
  • Mild Steel/ Epoxy painted
  • Maintenance Access
  • Ample space allotted for servicing
  • Engine Type (for Diesel)
  • Water cooled, four-stroke diesel engine
  • Painting/Coating
  • Epoxy coated for anti-corrosion
  • Start Mode
  • Auto/Manual/Electric Push Button Start
  • Protection Class
  • IP55
 

Industrial Fire Pump Room Trade Information

  • Minimum Order Quantity
  • 1 Unit
  • Payment Terms
  • Cash in Advance (CID)
  • Supply Ability
  • 10 Units Per Month
  • Delivery Time
  • 30 Days
  • Main Domestic Market
  • All India
 

About Industrial Fire Pump Room



Experience the impeccable protection of our Industrial Fire Pump Room-where opulence meets valiant engineering. Redeem advanced safety with a setup accommodating 2-3 fire pumps (main, standby, and jockey), equipped with water-cooled, four-stroke diesel engines and flexible couplings. The weatherproof, epoxy-coated, anti-corrosion enclosure ensures longevity, while BMS/fire panel integration enhances control. With flow rates up to 800 m3/h, pressures up to 16 bar, and compliance with NFPA 20/IS 15301/UL standards, our solution exemplifies fresh innovation for dependable, industrial fire defense.

Versatile Application Spaces and Types of Usage

The Industrial Fire Pump Room serves as a valiant defense for a broad array of facilities, including industrial complexes, warehouses, refineries, and commercial premises. Applications range from fire hydrant protection to sprinklers, deluge, and monitor systems. Fresh setups are suitable for both indoor and outdoor installation, offering flexible use as a main, standby, or jockey pump. This impeccable versatility ensures effective installation and operation across diverse industrial requirements, making it the premier choice for high-stakes fire safety.


Delivery Timeframes, Payment Terms, and Shipping Details

Delivery of the Industrial Fire Pump Room is managed with utmost precision, minimizing expenditure and ensuring seamless outlay. Typical delivery occurs within 4-8 weeks following order confirmation, while payment terms remain flexible-often facilitating advance purchase arrangements. Goods are usually shipped through reputable Indian FOB ports, allowing for secure national and international distribution. This assures clients of reliable, on-time delivery with transparent budgeting and expenditure control throughout the procurement and installation process.


FAQ's of Industrial Fire Pump Room:


Q: How does the fire pump room interface with building fire alarm or BMS systems?

A: The fire pump room features provisions for seamless integration with fire alarm panels or Building Management Systems (BMS), allowing for real-time monitoring, control, and enhanced reliability in emergency scenarios.

Q: What are the advantages of the weatherproof canopy and epoxy coating used in your fire pump setup?

A: The weatherproof canopy and epoxy coating ensure impeccable protection against harsh weather and corrosion, extending operational life and maintaining high performance even in challenging environments.

Q: When is it appropriate to use a diesel engine versus an electric motor for pump operation?

A: Diesel engines are preferred when a valiant backup power source is necessary or where electrical power may be unreliable, whereas electric motors suit environments with stable, continuous power supply.

Q: Where can the Industrial Fire Pump Room be installed?

A: Our fire pump rooms are engineered for both indoor and outdoor installation, adaptable to various sectors such as manufacturing facilities, refineries, warehouses, and large commercial sites.

Q: What is the process for ordering and installing an Industrial Fire Pump Room?

A: Clients initiate by providing site and application specifics. Our team then customizes the solution, delivers within the stipulated timeframe, and oversees installation and testing to ensure impeccable system readiness.

Q: How does the maintenance process benefit end-users?

A: Generous maintenance access is included in the design, enabling easy, cost-effective servicing that reduces downtime and prolongs the dependable performance of the entire fire pump system.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Fire Pump Room Category

MS Fire Pump Room

MS Fire Pump Room

Minimum Order Quantity : 1 Unit

Caliber : 100 mm

Pump Type : Other, End Suction / Split Case

Discharge Pressure : Up to 10 bar

Usage : Other, Fire Fighting / Emergency Water Supply

Power : Other, 15 HP to 40 HP

Fire Compresser Room

Fire Compresser Room

Minimum Order Quantity : 1 Unit

Caliber : 50 mm

Pump Type : Other, Centrifugal / Horizontal Split Casing

Discharge Pressure : 10 Bar

Usage : Other, Fire Fighting System

Power : Other, 5 HP / 7.5 HP / 10 HP



Back to top